- 品牌:其他
- 型号:WIKA MA1
- 额定电压:220
- 额定电流:15
- 产品认证:CE
- 加工定制:
额定电压: 220(v) 类型: 机械压力开关
最大工作压力: 100bar(pa) 型号: ma1
额定电流: 15(a) 品牌: wika/威卡
机械寿命: 100(万次) 产品认证: ce
加工定制: 是
these high-quality pressure switcheshavebeen developed especially for safety-critical applications.thehigh quality of the products ensures reliable monitoring ofyourplant. the manufacturer cella is certified to iso 9001.inproduction, the
switches are traced by quality assurance software at every stepandsubsequently are 100 % tested.
all wetted materials are madefromstainless steel as a standard. each switch family is availableinip65, ex-ia or ex-d versions.
in order to ensure as flexible operationaspossible, the pressure switches are equipped with microswitches,whichmake it possible to switch an electrical load of upto 15 a /ac 220 v directly. for smaller contact ratings, such asfor plcapplications, argon gas-filled micro switches withgold-platedcontacts can be selected as an option.
by using a diaphragm measuring system,themodel ma1 pressure switch is extremely robust andguaranteesoptimal operating characteristics. for applicationsrequiringparticularly high corrosion protection, variants with ptfeor
monel wetted parts are available.
switch points
the switch points can be set toyourrequirements, free-ofcharge.
please specify:
switch point, switching direction foreachcontact (e.g. switch point 1: 0.5 bar, falling, switch point 2:3bar, rising)
with two micro switches, the switchpointscan be set independently of each other.
afterunscrewing the case cover, switch point adjustment can bemadeusing the adjustment screw. the switch point is settable withintheentire measuring range with the following
general rule:
■ define the value a = 2 x repeatability+switch hysteresis
■ if the pressure is rising, theswitchpoint should be set between (min. + value a) up to max. ofthesetting range
■ if the pressure is falling, theswitchpoint should be set between min. up to (max. - value a) ofthesetting range
example:
setting range: 0 ... 1 bar with oneswitchcontact
repeatability: 1 % of 1 bar = 10mbar
switch hysteresis = 15 mbar (seetablesetting ranges)
value a = 2 x 10 mbar + 15 mbar =35mbar
if the pressure is rising, the switchpointshould be set between 35 mbar up to 1 bar.
if the pressure is falling, theswitchpoint should be set between 0 up to 965 mbar.
for optimal performance we suggesttheswitch point lies between 25 % and 75 % of thesettingrange.
electricalconnection
½ npt female, cable connectionusinginternal terminal block, protective conductor connectionusinginternal and xternal screw, max. earth cable cross-section4mm2
pressureswitchcertified per:
■ pressure equipment directive97/23/ec(ped, annex 1,category iv, safety accessories, module b +d)
■ low voltage directive 73/23 eec and93/68eec
dielectricstrength
safety class i (en61298-2:1997-06)
mounting
direct or wall mounting
preferred connection location oftheprocess connection should be below. alternatively theinstrumentcan be installed so that internal access is from thefront of theenclosure and the electrical connection is located ontheside.
weight
approx. 3.1 kg
options
■ other process connection, alsowithadapter
■ electrical connection 3/4 npt, g 1/2orm20 x 1.5 (female)
■ cable gland on request
■ 2 pipe-mounting kit (withclampingelement)
■ version for off-shore ortropicalisedapplication 9)
■ version for applications to nace9)10)
■ version for ammonia applications9)
■ oil and grease free version foroxygenapplications
■ accessories:
pressure gaugevalvesmodel 910.11, see data sheet ac 09.02
barstockvalvesmodel 910.81, see data sheet ac 09.18
9)inertgas filled contacts required
10) max. test pressure 100 bar onlywithsetting ranges 0 ... 16 bar and 0 ... 25 bar
11) max. 1 switch contact
approvalsandcertificates
■ sil 2 version9)11)
■ gost-r certificate
■ test certificate *ca* (confirmation oftheswitching accuracy)
■ test report *cp* (3-time listing of theswitchpoint, requires switch point specification)
■ material certificate 3.1 peren10204
orderinginformation
model / wetted parts / switch contactswithversion / setting range / process connection /electricalconnection / switch point(s) / switching direction(s)/options