| Negotiable |
200 Pieces
(MOQ)
|
Basic Info.
Heatsink Material
Plastic
Certificate
Ce,RoHS, ISO9001
Liquid
Hot or Cold Water, Beverage,
Motor
DC Motor, DC Brushless Motor,BLDC Motor
Pump Ideal Life Time
20,000 Hours
More Application
Cooling Circulating System
Transport Package
Standard Export Packing or OEM Packing
Specification
CE, ISO9001, FDA, RoHS
Production Capacity
100, 000 PCS/Month
Product Description
12V DC Computer Cooling Pump Circulation Pump
Application:
Water Dispenser/Water Coolers , Coffee Maker/Coffee Machine , Beverage Dispenser/Juice Machine
Water Purifier, Tea Maker, Milk Dspenser , Fountain, Hydroponics
Instant filtered drinking system
Features:
Advanced magnetic driving technology, static-seal without any leakage forever
High efficiency ECM brushless DC motor with long lifetime
Heavy duty work,can sustain 24 hours continuous running
Special designed high efficiency closed-impeller
Wide voltage range suitable for battery power supply
All wetted materials FDA certified (food safe)
Small size, light weight
Max temperature 105ºC
Durable permanent magnetic rotor and high density ceramic shaft
Specification:
| Model:TL-B03 |
| Model | Product Code | Max Water Flow (L/Min) | Rated Voltage(DC) | Rated Current (A) | Max Water Head(M) | Rated Power(W) |
| B03 | TL-B03-A12-0602 | 6.5 | 12 | 0.43 | 2.5 | 5.16 |
| TL-B03-A24-0602 | 6 | 24 | 0.22 | 2 | 5.28 |
| TL-B03-A12-0501 | 4.8 | 12 | 0.2 | 1.2 | 2.4 |
| Application Conditions |
| 1 | Environment temperature | -40~40ºC |
| The use of water temperature | -40~105ºC |
| 2 | Operation Surroundings | 70%RH and 100%RH |
| 3 | Working liquid | Pure Water,antifreeze,etc |
| 4 | IP Level | IP68 |
| 5 | Max pressure / Continue work Pressure | 1.8Mpa / 0.5Mpa |
Get more Technical data, please contact us !
Usage Note:
Dry-running is prohibited.
Reverse polarity is not allowed (except customized).
The pump if dropped or with heavy vibration do not use.
Liquid contain impurities or magnetic particles are not allowed.
Liquid temperature over 80°C is not allowed (except high temperature models).
Acidic or alkaline liquid is prohibited (except customized).
Company
Get more detail, please contact us !