Product Details
Product Details
Product Description
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
125800-01 350025
. Occlusion port 4. Select Start. The System Check starts and shows the results of each check. The system runs the following checks: • Paw transducer check • Barometric pressure check • Relief valve check • Exhalation valve check • Expiratory flow sensor check • Air flow sensor check • Oxygen sensor check • O2 flow sensor check • Resistance check • Circuit measurements check (circuit leak, compliance, and resistance) When performing the Resistance Check, the wye-piece and all breathing accessories such as: D-lite (+)/Pedi-lite(+) sensor and HME should remain on the occlusion port. 5. Select the information icon to see the System Check Details menu. The System Check starts and shows the results of each check. Follow all on-screen system check instructions. As the System Check runs, the results of each check are displayed as a green check mark (pass) or red X (fail). If a check fails, a Help icon displays next to the failed check (red X). Select the Help icon to view possible causes and help for troubleshooting a failure. Important Note CARESCAPE™ R860 6-8 2065490-001 When the System Check is complete, the Final Result line will display the patient type icon, a green check mark (pass) or red X (fail), and the date and time of the System Check. 6 Operation 2065490-001 6-9 Patient ventilation Setting the ventilator data source The data source is used to obtain patient monitoring parameters from either the ventilator or the airway module. See "Patient monitoring" for detailed information. See "Setting the ventilator data source"in the "Neonatal Operation" section. 1. Select Menu > System. The System menu shows. 2. Select Data Source. 3. Select Ventilator or Airway Module to confirm settings. If Ventilator is selected as the data source the Ventilator Data icon displays in the lower right corner of the display; the internal sensors of the ventilator will be the source for monitored data. If Airway Module is selected as the data source and an airway module is installed and warmed up, the Airway Module (Patient) data icon displays in the lowerright corner of the display. The airway module will be the first source for monitored data. If data is not available through the airway module, monitored data will come from the internal ventilator sensors. Ventilator Data Source Icons Ventilator data Airway Module (Patient) data When Airway Module is selected as the data source, the data source icon will not be updated until the module is able to provide data. This may take 2 to 5 minutes when a module is first installed into the module bay. Only data available from the installed airway module will be displayed on the ventilator, all other data will be from the ventilator. For example, if a module capable of measuring CO2 and O2 only is installed, CO2 and O2 data displayed will be from the module, all other data will be from the ventilator.xample, use th