Product Details
Product Description
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
The following section describes the setup of the ventilator. Follow all safety precautions and warnings. Make sure system batteries are fully charged before use. It is recommended that the ventilator maintain connection to the main power supply at all times to prevent battery discharge and degradation. A green LED indicator located on the front lower left of the display unit indicates (when illuminated) that the ventilator is connected to a main power source. Access to an appropriate alternative means of ventilation at all times is required to prevent patient injury or death in the event of ventilator failure. Do not modify the ventilator equipment without authorization of the manufacturer. Adding attachments or other components to the breathing system may change the pressure gradient. Ensure the inspiratory and expiratory resistance do not exceed 6 cmH2O for the following flows: • 30 l/min for adult use: VT >= 300 mL • 15 l/min for pediatric use: 300 mL >= VT >= 50 mL • 2.5 l/min for neonatal use: VT <= 50 mL Do not attach a gas scavenging system or other accessories to the gas exhaust port. Occluding the gas exhaust port will prevent proper ventilation for the patient. If sampled gas is returned to the breathing system, there is a risk of patient cross-infection. Use of other electrical equipment adjacent to or stacked with the ventilator may cause interference. If adjacent or stacked use is necessary, the ventilator should be observed to verify normal operation in the configuration in which it will be used. Use of portable phones or other radio frequency (RF) emitting equipment, which exceed electromagnetic interference levels specified in "Guidance and manufacturer’s declaration - electromagnetic immunity", near the ventilator may cause unexpected or adverse operation. Monitor the function of the ventilator when RF emitters are in the vicinity, including RFID readers and interrogators. The ventilator must not be used in a hyperbaric chamber