US$527.00-530.00
|
2 Pieces
(MOQ)
|
Basic Info.
Model Number
Testo 316-Ex
Different Types of Gas Can Be Detected
Methane, Propane and Hydrogen
Sensor
Flexible Probe for Inaccessible Areas
Operating Humidity
20 to 80 %Rh (Not Condensed)
Ex-Protection
II 2g Eex Ib Iic T1 (Ex Zone 1)
Operating Temperature
14° to 104 °f / -10 to +40 °c
Storage Temperature
14° to 122 °f / -10 to +50 °c
Battery Type
2 AA Batteries
Weight
Approx. 7 Oz. / Approx. 200 G
Transport Package
Color Box
Specification
100 pcs/ctn
Production Capacity
100000PCS/Year
Product Description
Original Testo Testo 316-EX, ATEX Gas Leak Detector (Intrinsically Safe)
Product Description ATEX approval (94/9/EC) ppm and vol.% display Flexible probe for inaccessible areas 3 different types of gas can be detected: methane, propane and hydrogen
Product DescriptionThe testo 316-EX gas leak detector helps you to detect gas leaks and ATEX protection means it can also be used in potentially explosive atmosphere. Gas verification and gas leak location can be carried out on gas pipes and installations both indoors and outdoors.
When house owners notify the network operator or fitter hat they can clearly smell gas in the house, a highly explosive gas concentration may already be present (4-17%). The fitter has to use a gas detector with ATEX protection for the basic checking of sections of gas pipes for leaktightness or to locate the leak. Because you have to be sure in a hazardous situation that the gas measuring technology being used does not cause an explosion through its own potential ignition sources.
The testo 316-EX gas leak detector offers this ATEX protection (ATEX approval 94/9/EC). Use the multi-range gas detector to detect methane, propane and hydrogen gases. The gas concentrations are measured in the ppm range with a semiconductor sensor and are shown on the display with a resolution of 1 ppm. Flexible measuring probes mean you can search for leaks even in inaccessible areas. testo 316-EX electronic gas leak detector with EX protection, including batteries, case, Allen key and calibration protocol. Specifiaction
Operating humidity 20 to 80 %RH (not condensed) |
Weight Approx. 200 g |
Reaction time 14 s t |
Dimensions 135 x 45 x 25 mm |
Operating temperature -10 to +40 °C |
Protection class IP54 |
EU-/EG-guidelines 94/9/EG (ATEX); EU-guideline 2014/30/EU |
Battery type 2 AA mignon batteries |
Battery life to 10 h |
Battery feature Type permitted for use in areas with danger of explosion: Camelion Plus Alkaline LR6 (see order data, order no. 0515 0316) |
Storage temperature -10 to +50 °C |
Ex-protection II 2G EEx ib IIC T1 (Ex Zone 1) |
|
Methane (CH)
Measuring range 1 ppm to 2.5 Vol.% CH |
Resolution 1 ppm / 0.1 Vol.% |
Lower response threshold 1 ppm |
Product photo