Product Details
Product Details
Product Description
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
N.145-18N.105-19 IB3110050
Use these instructions to install the display unit to a 10x25 mm, ISO 19054 rail system (medi-rail). Make sure that the display cable length is long enough to reach from the ventilator to the desired mounting location. See the "Parts and accessories" section for ordering information. 1. Align and seat the arm onto the rail system. Listen for an audible click of the secondary latch. 2. Close the primary latch to secure the arm onto the rail system. AB.100.059 Figure 4-14 • Display unit mounted on a rail system Note CARESCAPE™ R860 4-36 2065490-001 Installing the display unit on the ventilator 1. Firmly hold the display unit at the junction of the display arm and display screen. 2. Open the primary latch (1). 3. Press and hold the secondary release latch (2) to disengage the display unit from the remote rail. 4. Align the arm assembly with the receiver mount. Make sure the cable is positioned in the cable channel of the receiver mount. 5. Make sure the primary latch is open and seat the arm assembly onto the receiver mount. Listen for an audible click of the secondary latch. 6. Close the primary latch to secure the arm assembly onto the ventilator. AB.98.299 1 2 Figure 4-15 • Installing the display unit on the ventilator 4 Setup and connections 2065490-001 4-37 Connecting the auxiliary pressure tubing Auxiliary pressure is a supplementary pressure measurement that can be displayed with a waveform and patient data (measured data). 1. Attach the auxilliary pressure tubing to the Paux port by sliding the tubing over the barbed end of the port. AB.100.194 Figure 4-16 • Connecting the auxiliary pressure tubing 2. To display the Paux waveform follow the instruction in "Waveform settings" in the "Patient monitoring" section. 3. To disconnect the auxiliary pressure tubing from the Paux port; grasp the tubing and pull straight off from the barbed port. Purging the auxiliary pressure tubing Monitoring lines may become clogged and effect performance. To purge the line, complete the following steps. Purge flow will deliver 35 +/- 15 ml of air. Do not initiate purge flow when the Paux port is connected to a closed system such as an endotracheal cuff. 1. Disconnect the patient end of the tubing. 2. Select Menu > System. • Check the box to turn on Purge Flow. • Uncheck the box to turn off Purge Flow