Product Details
Product Description
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
VTexp low Medium Measured expired tidal volume was less than the VTexp low alarm limit for 3 breaths. Expired tidal volume is less than the low alarm limit. • Check the status of the patient. • Check for leaks in the patient circuit or airway. • Review the ventilator settings. • Review the VTexp low alarm limit in Alarm Setup. Measured airway module expired tidal volume was less than the VTexp low alarm limit for 3 seconds. Expired tidal volume is less than the low alarm limit. • Check the status of the patient. • Check for leaks in the patient circuit or airway. • Check the airway module spirometry tube connection. • Check for an occlusion in the airway module spirometry tube. • Review the ventilator settings. • Review the VTexp low alarm limit in Alarm Setup. Alarm filters When an alarm is active and another similar alarm becomes active, the original alarm may be filtered (or removed) from the alarm list. . Alarm Filters Active Alarm Filtered (removed) Alarms Expiratory flow sensor error VTexp low VTexp high MVexp high MVexp low Airway module error Airway module gas sampling error System shutdown in less than 1 minute System shutdown in less than 5 minutes System shutdown in less than 10 minutes System shutdown in less than 20 minutes Battery in use 8 Alarms and troubleshooting 2065490-001 8-25 Alarm Filters Active Alarm Filtered (removed) Alarms System shutdown in less than 5 minutes System shutdown in less than 10 minutes System shutdown in less than 20 minutes Battery in use System shutdown in less than 10 minutes System shutdown in less than 20 minutes Battery in use System shutdown in less than 20 minutes Battery in use Air and O2 supply pressure low Air supply pressure low O2 supply pressure low Inspiratory flow sensor error Flow control valve error Apnea VTexp low VTexp high MVexp high MVexp low RR low Patient Connection Leak Circuit Leak Patient Disconnected No patient effort Apnea Ppeak low